{"product_id":"pitacs-6181b-double-insulated-single-core-lszh-cable","title":"Pitacs 6181B Double Insulated Single Core LSZH Cable","description":"\u003ch2 data-section-id=\"q9ktj0\" data-start=\"0\" data-end=\"55\"\u003ePitacs 6181B Double Insulated Single Core LSZH Cable\u003c\/h2\u003e\n\u003cp data-start=\"57\" data-end=\"565\"\u003eThe Pitacs 6181B Double Insulated Single Core LSZH Cable is a professional grade Low Smoke Zero Halogen cable designed for fixed electrical installations where reduced smoke and acid gas emissions are essential in the event of a fire. Ideal for domestic, commercial and light industrial applications, this high performance cable is commonly used for consumer unit connections, meter tails and protected wiring installations in public buildings and enclosed environments. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"567\" data-end=\"1195\"\u003eManufactured with a Class 2 stranded copper conductor, cross-linked polyethylene insulation and an LSZH outer sheath, the Pitacs 6181B cable provides excellent durability, thermal performance and enhanced fire safety characteristics. Suitable for installation in dry or damp conditions, the cable can be clipped direct, installed on trays or routed through conduit and trunking systems where reliable fixed wiring performance is required. Manufactured to BS 7211:2012 standards and BASEC approved, this cable provides a dependable and compliant solution for modern electrical installations. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"1197\" data-end=\"1213\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1215\" data-end=\"1827\"\u003e\n\u003cli data-section-id=\"1v9699d\" data-start=\"1215\" data-end=\"1258\"\u003eDouble insulated single core LSZH cable\u003c\/li\u003e\n\u003cli data-section-id=\"784x2j\" data-start=\"1259\" data-end=\"1323\"\u003eLow Smoke Zero Halogen construction for enhanced fire safety\u003c\/li\u003e\n\u003cli data-section-id=\"ltweyx\" data-start=\"1324\" data-end=\"1361\"\u003eClass 2 stranded copper conductor\u003c\/li\u003e\n\u003cli data-section-id=\"1uj1ev6\" data-start=\"1362\" data-end=\"1402\"\u003eCross-linked polyethylene insulation\u003c\/li\u003e\n\u003cli data-section-id=\"1dxrgoz\" data-start=\"1403\" data-end=\"1461\"\u003eSuitable for consumer unit and meter tail applications\u003c\/li\u003e\n\u003cli data-section-id=\"1jq5akw\" data-start=\"1462\" data-end=\"1515\"\u003eDesigned for domestic and light industrial wiring\u003c\/li\u003e\n\u003cli data-section-id=\"vuj66p\" data-start=\"1516\" data-end=\"1559\"\u003eSuitable for dry and damp installations\u003c\/li\u003e\n\u003cli data-section-id=\"380n3o\" data-start=\"1560\" data-end=\"1619\"\u003eCan be installed in conduit, trunking and cable ducting\u003c\/li\u003e\n\u003cli data-section-id=\"tmajua\" data-start=\"1620\" data-end=\"1674\"\u003eSuitable for clipped direct and tray installations\u003c\/li\u003e\n\u003cli data-section-id=\"1mjj224\" data-start=\"1675\" data-end=\"1702\"\u003eRated voltage: 450\/750V\u003c\/li\u003e\n\u003cli data-section-id=\"1w7a91x\" data-start=\"1703\" data-end=\"1745\"\u003eManufactured to BS 7211:2012 standards\u003c\/li\u003e\n\u003cli data-section-id=\"1nj23ud\" data-start=\"1746\" data-end=\"1764\"\u003eBASEC approved\u003c\/li\u003e\n\u003cli data-section-id=\"1hwegwz\" data-start=\"1765\" data-end=\"1827\"\u003eCE and UKCA certified \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1ri58k4\" data-start=\"1829\" data-end=\"1865\"\u003eEnhanced Fire Safety Performance\u003c\/h3\u003e\n\u003cp data-start=\"1867\" data-end=\"2247\"\u003eThe Pitacs 6181B Double Insulated Single Core LSZH Cable is specifically designed for installations where smoke suppression and reduced toxic emissions are critical. Its LSZH construction helps minimise smoke density and corrosive gas release during fire conditions, making it particularly suitable for use in public buildings, apartment blocks, escape routes and enclosed spaces.\u003c\/p\u003e\n\u003cp data-start=\"2249\" data-end=\"2701\"\u003eThe stranded copper conductor allows for easier installation handling and dependable electrical conductivity, while the cross-linked polyethylene insulation supports higher operating temperatures than standard PVC alternatives. Suitable for fixed installation in conduit, trunking, cable trays and free air applications, the 6181B cable delivers reliable long term performance for professional electrical projects. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"858m9l\" data-start=\"2703\" data-end=\"2728\"\u003eTechnical Information\u003c\/h3\u003e\n\u003cul data-start=\"2730\" data-end=\"3230\"\u003e\n\u003cli data-section-id=\"12yj88d\" data-start=\"2730\" data-end=\"2758\"\u003eVoltage Rating: 450\/750V\u003c\/li\u003e\n\u003cli data-section-id=\"y9c1uj\" data-start=\"2759\" data-end=\"2789\"\u003eConductor Material: Copper\u003c\/li\u003e\n\u003cli data-section-id=\"1m7gexj\" data-start=\"2790\" data-end=\"2825\"\u003eConductor Type: Stranded Copper\u003c\/li\u003e\n\u003cli data-section-id=\"wk8n89\" data-start=\"2826\" data-end=\"2854\"\u003eConductor Class: Class 2\u003c\/li\u003e\n\u003cli data-section-id=\"106jm2b\" data-start=\"2855\" data-end=\"2912\"\u003eInsulation Material: Cross-linked Polyethylene (XLPE)\u003c\/li\u003e\n\u003cli data-section-id=\"1g748pa\" data-start=\"2913\" data-end=\"2944\"\u003eOuter Sheath Material: LSZH\u003c\/li\u003e\n\u003cli data-section-id=\"1exud02\" data-start=\"2945\" data-end=\"2969\"\u003eCable Profile: Round\u003c\/li\u003e\n\u003cli data-section-id=\"17d6nzn\" data-start=\"2970\" data-end=\"3011\"\u003eOperating Temperature: -15°C to +90°C\u003c\/li\u003e\n\u003cli data-section-id=\"uzmy7n\" data-start=\"3012\" data-end=\"3056\"\u003eMaximum Short Circuit Temperature: 250°C\u003c\/li\u003e\n\u003cli data-section-id=\"1qkeq67\" data-start=\"3057\" data-end=\"3103\"\u003eMinimum Bending Radius: 8 x cable diameter\u003c\/li\u003e\n\u003cli data-section-id=\"5qzn6y\" data-start=\"3104\" data-end=\"3147\"\u003eSuitable for indoor fixed installations\u003c\/li\u003e\n\u003cli data-section-id=\"h0v6kb\" data-start=\"3148\" data-end=\"3230\"\u003eNot suitable for underground installation \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"gw7fam\" data-start=\"3232\" data-end=\"3264\"\u003eAdditional Technical Details\u003c\/h3\u003e\n\u003cul data-start=\"3266\" data-end=\"3877\"\u003e\n\u003cli data-section-id=\"hpr6se\" data-start=\"3266\" data-end=\"3307\"\u003eStandards: BS 7211:2012 \/ BS EN 60228\u003c\/li\u003e\n\u003cli data-section-id=\"ph4h5w\" data-start=\"3308\" data-end=\"3353\"\u003eCertifications: BASEC, CE, ISO 9001, UKCA\u003c\/li\u003e\n\u003cli data-section-id=\"v6ofaa\" data-start=\"3354\" data-end=\"3393\"\u003eFlame Retardancy: BS EN\/IEC 60332-1\u003c\/li\u003e\n\u003cli data-section-id=\"1w9a0ey\" data-start=\"3394\" data-end=\"3428\"\u003eHalogen Free: IEC\/EN 60754-1\/2\u003c\/li\u003e\n\u003cli data-section-id=\"1ecph7o\" data-start=\"3429\" data-end=\"3466\"\u003eSmoke Emission Standard: EN 61034\u003c\/li\u003e\n\u003cli data-section-id=\"1267725\" data-start=\"3467\" data-end=\"3529\"\u003eApplication: Consumer units and fixed wiring installations\u003c\/li\u003e\n\u003cli data-section-id=\"x4t4sw\" data-start=\"3530\" data-end=\"3573\"\u003eAvailable sizes include 16mm² and 25mm²\u003c\/li\u003e\n\u003cli data-section-id=\"1i7ohc3\" data-start=\"3574\" data-end=\"3689\"\u003eAvailable sheath\/core combinations include Grey with Brown, Grey with Blue, Brown with Brown and Blue with Blue\u003c\/li\u003e\n\u003cli data-section-id=\"1vnpldp\" data-start=\"3690\" data-end=\"3755\"\u003eSupplied on drums in multiple cable lengths depending on size\u003c\/li\u003e\n\u003cli data-section-id=\"pp4ovm\" data-start=\"3756\" data-end=\"3877\"\u003eCurrent carrying capacities vary depending on installation method and cable size \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1ort0kt\" data-start=\"3879\" data-end=\"3900\"\u003eWhat’s in the Box\u003c\/h3\u003e\n\u003cul data-start=\"3902\" data-end=\"3961\"\u003e\n\u003cli data-section-id=\"o2r4gv\" data-start=\"3902\" data-end=\"3961\"\u003ePitacs 6181B Double Insulated Single Core LSZH Cable drum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3963\" data-end=\"4297\"\u003eThe Pitacs 6181B Double Insulated Single Core LSZH Cable offers a professional and compliant wiring solution for modern fixed installations, combining enhanced fire safety properties, durable LSZH construction and dependable electrical performance for consumer unit and distribution applications.\u003c\/p\u003e","brand":"Pitacs","offers":[{"title":"100m \/ 16mm \/ Grey (Blue)","offer_id":57605683708236,"sku":"6181B16BL100","price":230.99,"currency_code":"GBP","in_stock":true},{"title":"50m \/ 16mm \/ Grey (Blue)","offer_id":57605683741004,"sku":"6181B16BL50","price":112.99,"currency_code":"GBP","in_stock":true},{"title":"100m \/ 16mm \/ Grey (Brown)","offer_id":57605683773772,"sku":"6181B16BR100","price":230.99,"currency_code":"GBP","in_stock":true},{"title":"50m \/ 16mm \/ Grey (Brown)","offer_id":57605683806540,"sku":"6181B16BR50","price":112.99,"currency_code":"GBP","in_stock":true},{"title":"50m \/ 25mm \/ Blue (Blue)","offer_id":57605683839308,"sku":"6181B25BL\/BL50","price":195.99,"currency_code":"GBP","in_stock":true},{"title":"50m \/ 25mm \/ Brown (Brown)","offer_id":57605683872076,"sku":"6181B25BR\/BR50","price":195.99,"currency_code":"GBP","in_stock":true},{"title":"100m \/ 25mm \/ Grey (Blue)","offer_id":57605683904844,"sku":"6181B25BL100","price":383.99,"currency_code":"GBP","in_stock":true},{"title":"50m \/ 25mm \/ Grey (Blue)","offer_id":57605683937612,"sku":"6181B25BL50","price":195.99,"currency_code":"GBP","in_stock":true},{"title":"100m \/ 25mm \/ Grey (Brown)","offer_id":57605683970380,"sku":"6181B25BR100","price":383.99,"currency_code":"GBP","in_stock":true},{"title":"50m \/ 25mm \/ Grey (Brown)","offer_id":57605684003148,"sku":"6181B25BR50","price":195.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/3757\/4988\/files\/6181B-Grey-Blue-2000px.png?v=1779745087","url":"https:\/\/ioelectrics.co.uk\/products\/pitacs-6181b-double-insulated-single-core-lszh-cable","provider":"io Electrics","version":"1.0","type":"link"}