{"product_id":"pitacs-p12yy-12-core-yy-control-flex-cable","title":"Pitacs P12YY 12 Core YY Control Flex Cable","description":"\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-(--header-height)\" dir=\"auto\" data-turn-id=\"ca8dd9f7-89c5-49a4-83c3-79d78f106a2e\" data-turn-id-container=\"ca8dd9f7-89c5-49a4-83c3-79d78f106a2e\" data-testid=\"conversation-turn-111\" data-scroll-anchor=\"false\" data-turn=\"user\"\u003e\u003c\/section\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-6a0f8e4a-e610-83eb-99c7-ca5ef8ad5965-22\" data-turn-id-container=\"request-6a0f8e4a-e610-83eb-99c7-ca5ef8ad5965-22\" data-testid=\"conversation-turn-112\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"05cffd03-d68d-4b2d-a14a-0b7191e53ad1\" data-turn-start-message=\"true\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\"\u003e\n\u003ch2 data-section-id=\"zdc4vf\" data-start=\"0\" data-end=\"45\"\u003ePitacs P12YY 12 Core YY Control Flex Cable\u003c\/h2\u003e\n\u003cp data-start=\"47\" data-end=\"793\"\u003eThe Pitacs P12YY 12 Core YY Control Flex Cable is a high core count flexible control and instrumentation cable designed for complex measuring, monitoring and control applications in industrial, commercial and building services environments. Suitable for use in control panels, automation systems, manufacturing equipment, HVAC installations, process control networks and power stations, this cable is designed for situations where multiple control or signal circuits are required within a single, compact cable. It is intended for indoor use in dry or lightly damp environments where screening or mechanical armouring is not required.\u003c\/p\u003e\n\u003cp data-start=\"795\" data-end=\"1382\"\u003eManufactured using fine stranded Class 5 copper conductors with PVC insulation and a durable grey PVC outer sheath, the P12YY cable provides excellent flexibility despite its high core count. This makes it suitable for installation in confined spaces such as control cabinets, machinery panels and complex wiring systems. The 12 core configuration significantly reduces the need for multiple smaller cables, simplifying installation and improving overall system organisation.\u003c\/p\u003e\n\u003cp data-start=\"1384\" data-end=\"1761\"\u003eManufactured to BS EN 50525-2-11 standards, the Pitacs P12YY is part of the YY control cable range designed for general-purpose control and instrumentation circuits where reliable electrical performance and high core density are required in a flexible construction.\u003c\/p\u003e\n\u003chr data-start=\"1763\" data-end=\"1766\"\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"1768\" data-end=\"1784\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1786\" data-end=\"2500\"\u003e\n\u003cli data-section-id=\"2y1h0p\" data-start=\"1786\" data-end=\"1819\"\u003e12 core YY control flex cable\u003c\/li\u003e\n\u003cli data-section-id=\"dm2evt\" data-start=\"1820\" data-end=\"1863\"\u003eFine stranded Class 5 copper conductors\u003c\/li\u003e\n\u003cli data-section-id=\"1r1e7ih\" data-start=\"1864\" data-end=\"1903\"\u003ePVC insulation and PVC outer sheath\u003c\/li\u003e\n\u003cli data-section-id=\"jq4koi\" data-start=\"1904\" data-end=\"1964\"\u003eDesigned for complex control and instrumentation systems\u003c\/li\u003e\n\u003cli data-section-id=\"1f2w7uj\" data-start=\"1965\" data-end=\"2031\"\u003eSuitable for industrial automation and manufacturing equipment\u003c\/li\u003e\n\u003cli data-section-id=\"2arjkf\" data-start=\"2032\" data-end=\"2097\"\u003eIdeal for HVAC, building services and process control systems\u003c\/li\u003e\n\u003cli data-section-id=\"u426kh\" data-start=\"2098\" data-end=\"2156\"\u003eHigh core count reduces cable clutter in installations\u003c\/li\u003e\n\u003cli data-section-id=\"1w1cgow\" data-start=\"2157\" data-end=\"2221\"\u003eFlexible construction for routing in confined control panels\u003c\/li\u003e\n\u003cli data-section-id=\"4gv56u\" data-start=\"2222\" data-end=\"2278\"\u003eNumber-coded cores with green\/yellow earth conductor\u003c\/li\u003e\n\u003cli data-section-id=\"1vp0cll\" data-start=\"2279\" data-end=\"2306\"\u003eRated voltage: 300\/500V\u003c\/li\u003e\n\u003cli data-section-id=\"4sdlx4\" data-start=\"2307\" data-end=\"2341\"\u003eFlame retardant to IEC 60332-1\u003c\/li\u003e\n\u003cli data-section-id=\"17k9oza\" data-start=\"2342\" data-end=\"2500\"\u003eManufactured to BS EN 50525-2-11 standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1t921yz\" data-start=\"2507\" data-end=\"2557\"\u003eDesigned for High-Density Control Applications\u003c\/h3\u003e\n\u003cp data-start=\"2559\" data-end=\"3102\"\u003eThe Pitacs P12YY 12 Core YY Control Flex Cable is intended for installations requiring a large number of control or signal circuits within a single cable assembly. It is commonly used in industrial control systems, automation panels and machinery where multiple signals need to be routed efficiently and reliably. The unshielded YY construction makes it suitable for internal installations where electromagnetic interference is not a primary concern.\u003c\/p\u003e\n\u003cp data-start=\"3104\" data-end=\"3447\"\u003eThe fine stranded copper conductors provide good flexibility and electrical performance, allowing the cable to be installed in complex routing paths within control cabinets and equipment enclosures. The 12 core design helps streamline wiring layouts, reducing installation time and improving system clarity compared to multiple smaller cables.\u003c\/p\u003e\n\u003ch3 data-start=\"3104\" data-end=\"3447\"\u003eTechnical Information\u003c\/h3\u003e\n\u003cul data-start=\"3481\" data-end=\"4080\"\u003e\n\u003cli data-section-id=\"10r8myw\" data-start=\"3481\" data-end=\"3509\"\u003eVoltage Rating: 300\/500V\u003c\/li\u003e\n\u003cli data-section-id=\"y9c1uj\" data-start=\"3510\" data-end=\"3540\"\u003eConductor Material: Copper\u003c\/li\u003e\n\u003cli data-section-id=\"1guaiix\" data-start=\"3541\" data-end=\"3591\"\u003eConductor Type: Fine stranded copper (Class 5)\u003c\/li\u003e\n\u003cli data-section-id=\"1dpwktd\" data-start=\"3592\" data-end=\"3623\"\u003eCore Configuration: 12 Core\u003c\/li\u003e\n\u003cli data-section-id=\"1d3h8zw\" data-start=\"3624\" data-end=\"3652\"\u003eInsulation Material: PVC\u003c\/li\u003e\n\u003cli data-section-id=\"1hax8h2\" data-start=\"3653\" data-end=\"3683\"\u003eOuter Sheath Material: PVC\u003c\/li\u003e\n\u003cli data-section-id=\"1ibveu4\" data-start=\"3684\" data-end=\"3725\"\u003eOperating Temperature: -15°C to +60°C\u003c\/li\u003e\n\u003cli data-section-id=\"14a32go\" data-start=\"3726\" data-end=\"3762\"\u003eShort Circuit Temperature: 150°C\u003c\/li\u003e\n\u003cli data-section-id=\"lrxsxz\" data-start=\"3763\" data-end=\"3852\"\u003eMinimum Bending Radius: approx. 4 × cable diameter (typical YY installation guidance)\u003c\/li\u003e\n\u003cli data-section-id=\"18qewyq\" data-start=\"3853\" data-end=\"3910\"\u003eSuitable for indoor dry and lightly damp environments\u003c\/li\u003e\n\u003cli data-section-id=\"us7rr2\" data-start=\"3911\" data-end=\"4080\"\u003eDesigned for control and instrumentation applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4082\" data-end=\"4085\"\u003e\n\u003ch3 data-section-id=\"gw7fam\" data-start=\"4087\" data-end=\"4119\"\u003eAdditional Technical Details\u003c\/h3\u003e\n\u003cul data-start=\"4121\" data-end=\"4776\"\u003e\n\u003cli data-section-id=\"gqb2s0\" data-start=\"4121\" data-end=\"4146\"\u003eUK designation: P12YY\u003c\/li\u003e\n\u003cli data-section-id=\"17rx6v9\" data-start=\"4147\" data-end=\"4178\"\u003eStandards: BS EN 50525-2-11\u003c\/li\u003e\n\u003cli data-section-id=\"u5gf0p\" data-start=\"4179\" data-end=\"4242\"\u003eCore identification: numbered cores plus green\/yellow earth\u003c\/li\u003e\n\u003cli data-section-id=\"18n2oy8\" data-start=\"4243\" data-end=\"4266\"\u003eSheath colour: grey\u003c\/li\u003e\n\u003cli data-section-id=\"189v5hy\" data-start=\"4267\" data-end=\"4326\"\u003eSuitable for control panels and internal wiring systems\u003c\/li\u003e\n\u003cli data-section-id=\"fv3fen\" data-start=\"4327\" data-end=\"4403\"\u003eIdeal for manufacturing, engineering and building services installations\u003c\/li\u003e\n\u003cli data-section-id=\"1xk3u50\" data-start=\"4404\" data-end=\"4566\"\u003eAvailable in multiple conductor size commonly 0.75mm²\u003c\/li\u003e\n\u003cli data-section-id=\"nhq5u1\" data-start=\"4567\" data-end=\"4631\"\u003eSupplied in coils or drum lengths depending on specification\u003c\/li\u003e\n\u003cli data-section-id=\"17w0z1b\" data-start=\"4632\" data-end=\"4720\"\u003eCurrent carrying capacity varies depending on conductor size and installation method\u003c\/li\u003e\n\u003cli data-section-id=\"11gkyjn\" data-start=\"4721\" data-end=\"4776\"\u003eDesigned for high core density control applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1ort0kt\" data-start=\"4783\" data-end=\"4804\"\u003eWhat’s in the Box\u003c\/h3\u003e\n\u003cul data-start=\"4806\" data-end=\"4865\"\u003e\n\u003cli data-section-id=\"1lgg2d9\" data-start=\"4806\" data-end=\"4865\"\u003ePitacs P12YY 12 Core YY Control Flex Cable (coil or drum)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wv8cei\" data-start=\"4872\" data-end=\"4883\"\u003eSummary\u003c\/h3\u003e\n\u003cp data-start=\"4885\" data-end=\"5298\"\u003eThe Pitacs P12YY 12 Core YY Control Flex Cable provides a high-capacity and flexible solution for complex control and instrumentation wiring. With its fine stranded copper conductors, PVC construction and efficient multi-core design, it is ideal for industrial control panels, automation systems and building services installations where a large number of circuits must be managed within a single, reliable cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"Pitacs","offers":[{"title":"1m \/ 0.75mm \/ Grey (Numbered Black Green\/Yellow)","offer_id":57726764712268,"sku":"P12YY0.75D1","price":1.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/3757\/4988\/files\/Control-P12YY-2000px.png?v=1780352887","url":"https:\/\/ioelectrics.co.uk\/products\/pitacs-p12yy-12-core-yy-control-flex-cable","provider":"io Electrics","version":"1.0","type":"link"}