{"product_id":"pitacs-p3cy-3-core-cy-control-flex-cable","title":"Pitacs P3CY 3 Core CY Control Flex Cable","description":"\u003ch2 data-section-id=\"ajs5fv\" data-start=\"0\" data-end=\"43\"\u003ePitacs P3CY 3 Core CY Control Flex Cable\u003c\/h2\u003e\n\u003cp data-start=\"45\" data-end=\"544\"\u003eThe Pitacs P3CY 3 Core CY Control Flex Cable is a screened flexible control cable designed for measuring, monitoring and control applications in industrial, commercial and engineering environments. Suitable for machinery, manufacturing systems, HVAC installations, power stations and automation equipment, this cable provides reliable signal transmission with effective protection against electrical interference, making it ideal for sensitive control circuits. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"546\" data-end=\"1015\"\u003eManufactured with fine stranded Class 5 copper conductors and a durable PVC insulation and sheath, the P3CY cable is designed for flexibility and ease of installation in control panels and equipment wiring. The key feature of this cable is its tinned copper wire braid screen, which provides protection against electromagnetic interference (EMI), ensuring stable and accurate signal transmission in electrically noisy environments. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1017\" data-end=\"1275\"\u003eManufactured to BS EN 50525-2-11 standards, the Pitacs P3CY is intended for indoor use in dry or damp conditions and is widely used where interference-free performance is critical for instrumentation and control systems. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"1282\" data-end=\"1298\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1300\" data-end=\"1927\"\u003e\n\u003cli data-section-id=\"1lactji\" data-start=\"1300\" data-end=\"1341\"\u003e3 core CY screened control flex cable\u003c\/li\u003e\n\u003cli data-section-id=\"dm2evt\" data-start=\"1342\" data-end=\"1385\"\u003eFine stranded Class 5 copper conductors\u003c\/li\u003e\n\u003cli data-section-id=\"1oz7czz\" data-start=\"1386\" data-end=\"1440\"\u003eTinned copper wire braid screen for EMI protection\u003c\/li\u003e\n\u003cli data-section-id=\"1jklwtj\" data-start=\"1441\" data-end=\"1499\"\u003eDesigned for measuring, monitoring and control systems\u003c\/li\u003e\n\u003cli data-section-id=\"75tmrj\" data-start=\"1500\" data-end=\"1561\"\u003eSuitable for industrial machinery and automation circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1bunb9i\" data-start=\"1562\" data-end=\"1609\"\u003eIdeal for HVAC and building control systems\u003c\/li\u003e\n\u003cli data-section-id=\"1adhuzd\" data-start=\"1610\" data-end=\"1671\"\u003eFlexible construction for easier routing and installation\u003c\/li\u003e\n\u003cli data-section-id=\"1i2yhmo\" data-start=\"1672\" data-end=\"1716\"\u003ePVC insulation and grey PVC outer sheath\u003c\/li\u003e\n\u003cli data-section-id=\"1jazbjd\" data-start=\"1717\" data-end=\"1766\"\u003eSuitable for dry and damp indoor environments\u003c\/li\u003e\n\u003cli data-section-id=\"1vp0cll\" data-start=\"1767\" data-end=\"1794\"\u003eRated voltage: 300\/500V\u003c\/li\u003e\n\u003cli data-section-id=\"1bf8ttx\" data-start=\"1795\" data-end=\"1842\"\u003eFlame retardant construction to IEC 60332-1\u003c\/li\u003e\n\u003cli data-section-id=\"l44t6g\" data-start=\"1843\" data-end=\"1927\"\u003eManufactured to BS EN 50525-2-11 standards \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"frk8i9\" data-start=\"1934\" data-end=\"1982\"\u003eReliable Signal Integrity in Control Systems\u003c\/h3\u003e\n\u003cp data-start=\"1984\" data-end=\"2383\"\u003eThe Pitacs P3CY 3 Core CY Control Flex Cable is specifically designed for applications where electrical noise can impact performance. The copper wire braid screen provides effective shielding against interference from motors, switching gear and industrial equipment, helping maintain clean and stable signal transmission in control and instrumentation circuits. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2385\" data-end=\"2686\"\u003eIts fine stranded copper conductors ensure excellent flexibility, making it easy to install in confined spaces such as control panels, ducts and machinery housings. This combination of flexibility and shielding makes it a dependable choice for complex control systems requiring consistent performance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"858m9l\" data-start=\"2693\" data-end=\"2718\"\u003eTechnical Information\u003c\/h3\u003e\n\u003cul data-start=\"2720\" data-end=\"3213\"\u003e\n\u003cli data-section-id=\"10r8myw\" data-start=\"2720\" data-end=\"2748\"\u003eVoltage Rating: 300\/500V\u003c\/li\u003e\n\u003cli data-section-id=\"y9c1uj\" data-start=\"2749\" data-end=\"2779\"\u003eConductor Material: Copper\u003c\/li\u003e\n\u003cli data-section-id=\"1guaiix\" data-start=\"2780\" data-end=\"2830\"\u003eConductor Type: Fine stranded copper (Class 5)\u003c\/li\u003e\n\u003cli data-section-id=\"18m57gx\" data-start=\"2831\" data-end=\"2861\"\u003eCore Configuration: 3 Core\u003c\/li\u003e\n\u003cli data-section-id=\"1d3h8zw\" data-start=\"2862\" data-end=\"2890\"\u003eInsulation Material: PVC\u003c\/li\u003e\n\u003cli data-section-id=\"1hax8h2\" data-start=\"2891\" data-end=\"2921\"\u003eOuter Sheath Material: PVC\u003c\/li\u003e\n\u003cli data-section-id=\"1v4pe7g\" data-start=\"2922\" data-end=\"2958\"\u003eScreen: Tinned copper wire braid\u003c\/li\u003e\n\u003cli data-section-id=\"1ibveu4\" data-start=\"2959\" data-end=\"3000\"\u003eOperating Temperature: -15°C to +60°C\u003c\/li\u003e\n\u003cli data-section-id=\"1xycequ\" data-start=\"3001\" data-end=\"3043\"\u003eShort Circuit Temperature: up to 150°C\u003c\/li\u003e\n\u003cli data-section-id=\"1jvq5dt\" data-start=\"3044\" data-end=\"3112\"\u003eMinimum Bending Radius: 4–5 × cable diameter (depending on size)\u003c\/li\u003e\n\u003cli data-section-id=\"1pbl8h6\" data-start=\"3113\" data-end=\"3213\"\u003eSuitable for indoor installations (dry or damp conditions) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"gw7fam\" data-start=\"3220\" data-end=\"3252\"\u003eAdditional Technical Details\u003c\/h3\u003e\n\u003cul data-start=\"3254\" data-end=\"3778\"\u003e\n\u003cli data-section-id=\"15arf3u\" data-start=\"3254\" data-end=\"3278\"\u003eUK designation: P3CY\u003c\/li\u003e\n\u003cli data-section-id=\"17rx6v9\" data-start=\"3279\" data-end=\"3310\"\u003eStandards: BS EN 50525-2-11\u003c\/li\u003e\n\u003cli data-section-id=\"u5gf0p\" data-start=\"3311\" data-end=\"3374\"\u003eCore identification: numbered cores plus green\/yellow earth\u003c\/li\u003e\n\u003cli data-section-id=\"18n2oy8\" data-start=\"3375\" data-end=\"3398\"\u003eSheath colour: grey\u003c\/li\u003e\n\u003cli data-section-id=\"d3w8r1\" data-start=\"3399\" data-end=\"3456\"\u003eDesigned for instrumentation and control applications\u003c\/li\u003e\n\u003cli data-section-id=\"vvzkoj\" data-start=\"3457\" data-end=\"3515\"\u003eSuitable for manufacturing and process control systems\u003c\/li\u003e\n\u003cli data-section-id=\"1f7cv7l\" data-start=\"3516\" data-end=\"3588\"\u003eAvailable in multiple conductor sizes 0.75mm², 1.0mm², 1.5mm²\u003c\/li\u003e\n\u003cli data-section-id=\"nhq5u1\" data-start=\"3589\" data-end=\"3653\"\u003eSupplied in coils or drum lengths depending on specification\u003c\/li\u003e\n\u003cli data-section-id=\"18cgtia\" data-start=\"3654\" data-end=\"3734\"\u003eCurrent carrying capacity varies with conductor size and installation method\u003c\/li\u003e\n\u003cli data-section-id=\"12kysg6\" data-start=\"3735\" data-end=\"3778\"\u003eDesigned for EMI-sensitive environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1ort0kt\" data-start=\"3785\" data-end=\"3806\"\u003eWhat’s in the Box\u003c\/h3\u003e\n\u003cul data-start=\"3808\" data-end=\"3865\"\u003e\n\u003cli data-section-id=\"k3zzh9\" data-start=\"3808\" data-end=\"3865\"\u003ePitacs P3CY 3 Core CY Control Flex Cable (coil or drum)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wv8cei\" data-start=\"3872\" data-end=\"3883\"\u003eSummary\u003c\/h3\u003e\n\u003cp data-start=\"3885\" data-end=\"4273\"\u003eThe Pitacs P3CY 3 Core CY Control Flex Cable provides a reliable and interference-protected solution for control and instrumentation wiring. With its tinned copper braid screen, fine stranded copper conductors and flexible PVC construction, it is designed for accurate signal transmission in industrial, commercial and HVAC control systems where performance and reliability are essential.\u003c\/p\u003e","brand":"Pitacs","offers":[{"title":"1m \/ 0.75mm \/ Grey (Numbered Black Green\/Yellow)","offer_id":57726767890764,"sku":"P3CY0.75D1","price":1.99,"currency_code":"GBP","in_stock":true},{"title":"1m \/ 1mm \/ Grey (Numbered Black Green\/Yellow)","offer_id":57726767923532,"sku":"P3CY1.0D1","price":1.99,"currency_code":"GBP","in_stock":true},{"title":"100m \/ 1.5mm \/ Grey (Numbered Black Green\/Yellow)","offer_id":57726767956300,"sku":"P3CY1.5D100","price":96.99,"currency_code":"GBP","in_stock":true},{"title":"1m \/ 1.5mm \/ Grey (Numbered Black Green\/Yellow)","offer_id":57726767989068,"sku":"P3CY1.5D1","price":1.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/3757\/4988\/files\/Control-P3CY-2000px.png?v=1780350016","url":"https:\/\/ioelectrics.co.uk\/products\/pitacs-p3cy-3-core-cy-control-flex-cable","provider":"io Electrics","version":"1.0","type":"link"}