{"product_id":"pitacs-p3sy-3-core-sy-control-flex-cable","title":"Pitacs P3SY 3 Core SY Control Flex Cable","description":"\u003ch2 data-section-id=\"1lk32j\" data-start=\"0\" data-end=\"43\"\u003ePitacs P3SY 3 Core SY Control Flex Cable\u003c\/h2\u003e\n\u003cp data-start=\"45\" data-end=\"693\"\u003eThe Pitacs P3SY 3 Core SY Control Flex Cable is a screened control cable designed for measuring, monitoring and control applications in industrial, commercial and engineering environments. Suitable for machinery, manufacturing systems, HVAC installations, power stations and automated control equipment, this cable provides reliable signal transmission while offering enhanced mechanical protection, making it ideal for control circuits operating in demanding installation conditions. It is commonly used where both signal integrity and physical durability are required within a flexible control wiring system. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"695\" data-end=\"1169\"\u003eManufactured with fine stranded Class 5 copper conductors and PVC insulation, the P3SY cable is designed for flexibility and ease of installation in control panels and equipment wiring systems. Unlike CY variants which use a copper braid screen, SY cables use a galvanised steel wire braid, providing mechanical protection against crushing, abrasion and general site damage while still allowing flexible installation in confined spaces. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1171\" data-end=\"1457\"\u003eManufactured to BS EN 50525-2-11 standards, the Pitacs P3SY is intended for indoor use in dry or damp environments and is widely specified in industrial control systems where mechanical robustness is as important as reliable electrical performance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"1464\" data-end=\"1480\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1482\" data-end=\"2108\"\u003e\n\u003cli data-section-id=\"iy57ry\" data-start=\"1482\" data-end=\"1523\"\u003e3 core SY screened control flex cable\u003c\/li\u003e\n\u003cli data-section-id=\"dm2evt\" data-start=\"1524\" data-end=\"1567\"\u003eFine stranded Class 5 copper conductors\u003c\/li\u003e\n\u003cli data-section-id=\"hds90t\" data-start=\"1568\" data-end=\"1625\"\u003eGalvanised steel wire braid for mechanical protection\u003c\/li\u003e\n\u003cli data-section-id=\"1jklwtj\" data-start=\"1626\" data-end=\"1684\"\u003eDesigned for measuring, monitoring and control systems\u003c\/li\u003e\n\u003cli data-section-id=\"75tmrj\" data-start=\"1685\" data-end=\"1746\"\u003eSuitable for industrial machinery and automation circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1bunb9i\" data-start=\"1747\" data-end=\"1794\"\u003eIdeal for HVAC and building control systems\u003c\/li\u003e\n\u003cli data-section-id=\"1rncpm3\" data-start=\"1795\" data-end=\"1862\"\u003eFlexible construction for easier installation in control panels\u003c\/li\u003e\n\u003cli data-section-id=\"qp2mdg\" data-start=\"1863\" data-end=\"1903\"\u003eGrey PVC outer sheath for durability\u003c\/li\u003e\n\u003cli data-section-id=\"4gv56u\" data-start=\"1904\" data-end=\"1960\"\u003eNumber-coded cores with green\/yellow earth conductor\u003c\/li\u003e\n\u003cli data-section-id=\"1vp0cll\" data-start=\"1961\" data-end=\"1988\"\u003eRated voltage: 300\/500V\u003c\/li\u003e\n\u003cli data-section-id=\"4sdlx4\" data-start=\"1989\" data-end=\"2023\"\u003eFlame retardant to IEC 60332-1\u003c\/li\u003e\n\u003cli data-section-id=\"l44t6g\" data-start=\"2024\" data-end=\"2108\"\u003eManufactured to BS EN 50525-2-11 standards \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"kgd7p0\" data-start=\"2115\" data-end=\"2168\"\u003eMechanical Protection for Industrial Environments\u003c\/h3\u003e\n\u003cp data-start=\"2170\" data-end=\"2556\"\u003eThe Pitacs P3SY 3 Core SY Control Flex Cable is designed for environments where cables may be exposed to mechanical stress such as abrasion, light impact or accidental crushing. The galvanised steel wire braid provides a protective layer around the cable, improving durability compared with standard unscreened or lightly protected flexible cables. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2558\" data-end=\"2876\"\u003eThe fine stranded copper conductors ensure reliable electrical performance and flexibility, making the cable suitable for installation in machinery, ducts, trunking and control cabinets. The 3 core configuration supports basic control and monitoring circuits while maintaining a compact and easy to route cable design.\u003c\/p\u003e\n\u003ch3 data-section-id=\"858m9l\" data-start=\"2883\" data-end=\"2908\"\u003eTechnical Information\u003c\/h3\u003e\n\u003cul data-start=\"2910\" data-end=\"3378\"\u003e\n\u003cli data-section-id=\"10r8myw\" data-start=\"2910\" data-end=\"2938\"\u003eVoltage Rating: 300\/500V\u003c\/li\u003e\n\u003cli data-section-id=\"y9c1uj\" data-start=\"2939\" data-end=\"2969\"\u003eConductor Material: Copper\u003c\/li\u003e\n\u003cli data-section-id=\"1guaiix\" data-start=\"2970\" data-end=\"3020\"\u003eConductor Type: Fine stranded copper (Class 5)\u003c\/li\u003e\n\u003cli data-section-id=\"18m57gx\" data-start=\"3021\" data-end=\"3051\"\u003eCore Configuration: 3 Core\u003c\/li\u003e\n\u003cli data-section-id=\"1d3h8zw\" data-start=\"3052\" data-end=\"3080\"\u003eInsulation Material: PVC\u003c\/li\u003e\n\u003cli data-section-id=\"1hax8h2\" data-start=\"3081\" data-end=\"3111\"\u003eOuter Sheath Material: PVC\u003c\/li\u003e\n\u003cli data-section-id=\"f5j403\" data-start=\"3112\" data-end=\"3156\"\u003eScreen: Galvanised steel wire braid (SY)\u003c\/li\u003e\n\u003cli data-section-id=\"1ibveu4\" data-start=\"3157\" data-end=\"3198\"\u003eOperating Temperature: -15°C to +60°C\u003c\/li\u003e\n\u003cli data-section-id=\"14a32go\" data-start=\"3199\" data-end=\"3235\"\u003eShort Circuit Temperature: 150°C\u003c\/li\u003e\n\u003cli data-section-id=\"z54r9z\" data-start=\"3236\" data-end=\"3290\"\u003eMinimum Bending Radius: approx. 5 × cable diameter\u003c\/li\u003e\n\u003cli data-section-id=\"1h4ilf8\" data-start=\"3291\" data-end=\"3378\"\u003eSuitable for indoor dry and damp environments \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"gw7fam\" data-start=\"3385\" data-end=\"3417\"\u003eAdditional Technical Details\u003c\/h3\u003e\n\u003cul data-start=\"3419\" data-end=\"4046\"\u003e\n\u003cli data-section-id=\"15b2zvu\" data-start=\"3419\" data-end=\"3443\"\u003eUK designation: P3SY\u003c\/li\u003e\n\u003cli data-section-id=\"17rx6v9\" data-start=\"3444\" data-end=\"3475\"\u003eStandards: BS EN 50525-2-11\u003c\/li\u003e\n\u003cli data-section-id=\"u5gf0p\" data-start=\"3476\" data-end=\"3539\"\u003eCore identification: numbered cores plus green\/yellow earth\u003c\/li\u003e\n\u003cli data-section-id=\"1501buk\" data-start=\"3540\" data-end=\"3593\"\u003eSheath colour: clear or grey depending on variant\u003c\/li\u003e\n\u003cli data-section-id=\"mmtfcg\" data-start=\"3594\" data-end=\"3646\"\u003eSuitable for instrumentation and control systems\u003c\/li\u003e\n\u003cli data-section-id=\"1djx2ej\" data-start=\"3647\" data-end=\"3721\"\u003eIdeal for manufacturing, process control and engineering installations\u003c\/li\u003e\n\u003cli data-section-id=\"6d37j9\" data-start=\"3722\" data-end=\"3830\"\u003eAvailable in multiple conductor sizes commonly 1.5mm², 2.5mm² and 4.0mm²\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"nhq5u1\" data-start=\"3831\" data-end=\"3895\"\u003eSupplied in coils or drum lengths depending on specification\u003c\/li\u003e\n\u003cli data-section-id=\"17w0z1b\" data-start=\"3896\" data-end=\"3984\"\u003eCurrent carrying capacity varies depending on conductor size and installation method\u003c\/li\u003e\n\u003cli data-section-id=\"a7kl6u\" data-start=\"3985\" data-end=\"4046\"\u003eDesigned for environments requiring mechanical protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1ort0kt\" data-start=\"4053\" data-end=\"4074\"\u003eWhat’s in the Box\u003c\/h3\u003e\n\u003cul data-start=\"4076\" data-end=\"4133\"\u003e\n\u003cli data-section-id=\"7hqjbx\" data-start=\"4076\" data-end=\"4133\"\u003ePitacs P3SY 3 Core SY Control Flex Cable (coil or drum)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wv8cei\" data-start=\"4140\" data-end=\"4151\"\u003eSummary\u003c\/h3\u003e\n\u003cp data-start=\"4153\" data-end=\"4539\"\u003eThe Pitacs P3SY 3 Core SY Control Flex Cable provides a mechanically protected solution for control and instrumentation wiring. With its galvanised steel wire braid, fine stranded copper conductors and flexible PVC construction, it delivers reliable performance in industrial, commercial and building control systems where both electrical integrity and physical durability are required.\u003c\/p\u003e","brand":"Pitacs","offers":[{"title":"100m \/ 1.5mm \/ Clear (Numbered Black Green\/Yellow)","offer_id":57726765564236,"sku":"P3SY1.5D100","price":112.99,"currency_code":"GBP","in_stock":true},{"title":"1m \/ 1.5mm \/ Clear (Numbered Black Green\/Yellow)","offer_id":57726765597004,"sku":"P3SY1.5D1","price":1.99,"currency_code":"GBP","in_stock":true},{"title":"100m \/ 2.5mm \/ Clear (Numbered Black Green\/Yellow)","offer_id":57726765629772,"sku":"P3SY2.5D100","price":163.99,"currency_code":"GBP","in_stock":true},{"title":"1m \/ 2.5mm \/ Clear (Numbered Black Green\/Yellow)","offer_id":57726765662540,"sku":"P3SY2.5D1","price":1.99,"currency_code":"GBP","in_stock":true},{"title":"1m \/ 4mm \/ Clear (Numbered Black Green\/Yellow)","offer_id":57726765695308,"sku":"P3SY4.0D1","price":2.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/3757\/4988\/files\/Control-P3SY-2000px.png?v=1780350833","url":"https:\/\/ioelectrics.co.uk\/products\/pitacs-p3sy-3-core-sy-control-flex-cable","provider":"io Electrics","version":"1.0","type":"link"}