{"product_id":"pitacs-p5cy-5-core-cy-control-flex-cable","title":"Pitacs P5CY 5 Core CY Control Flex Cable","description":"\u003ch2 data-section-id=\"1dbqqh7\" data-start=\"0\" data-end=\"43\"\u003ePitacs P5CY 5 Core CY Control Flex Cable\u003c\/h2\u003e\n\u003cp data-start=\"45\" data-end=\"684\"\u003eThe Pitacs P5CY 5 Core CY Control Flex Cable is a screened flexible control cable designed for measuring, monitoring and control applications in industrial, commercial and engineering environments. Suitable for machinery, manufacturing systems, HVAC installations, power stations and automation equipment, this cable is engineered to provide reliable signal transmission with effective protection against electromagnetic interference (EMI), making it ideal for sensitive control and instrumentation circuits.\u003c\/p\u003e\n\u003cp data-start=\"686\" data-end=\"1248\"\u003eManufactured with fine stranded Class 5 copper conductors and durable PVC insulation and sheath, the P5CY cable offers excellent flexibility for installation in control panels, machinery and equipment wiring systems. The key feature is its tinned copper wire braid screen, which provides high levels of protection against electrical interference, ensuring stable and accurate signal transmission in electrically noisy environments.\u003c\/p\u003e\n\u003cp data-start=\"1250\" data-end=\"1547\"\u003eManufactured to BS EN 50525-2-11 standards and designed for indoor use in dry or damp conditions, the Pitacs P5CY is widely used where interference-free operation is essential for reliable control and monitoring performance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"1554\" data-end=\"1570\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1572\" data-end=\"2276\"\u003e\n\u003cli data-section-id=\"zcyrgo\" data-start=\"1572\" data-end=\"1613\"\u003e5 core CY screened control flex cable\u003c\/li\u003e\n\u003cli data-section-id=\"dm2evt\" data-start=\"1614\" data-end=\"1657\"\u003eFine stranded Class 5 copper conductors\u003c\/li\u003e\n\u003cli data-section-id=\"1oz7czz\" data-start=\"1658\" data-end=\"1712\"\u003eTinned copper wire braid screen for EMI protection\u003c\/li\u003e\n\u003cli data-section-id=\"1jklwtj\" data-start=\"1713\" data-end=\"1771\"\u003eDesigned for measuring, monitoring and control systems\u003c\/li\u003e\n\u003cli data-section-id=\"1457rsj\" data-start=\"1772\" data-end=\"1831\"\u003eSuitable for industrial automation and machinery wiring\u003c\/li\u003e\n\u003cli data-section-id=\"30dv1u\" data-start=\"1832\" data-end=\"1882\"\u003eIdeal for HVAC and building management systems\u003c\/li\u003e\n\u003cli data-section-id=\"1rncpm3\" data-start=\"1883\" data-end=\"1950\"\u003eFlexible construction for easier installation in control panels\u003c\/li\u003e\n\u003cli data-section-id=\"qp2mdg\" data-start=\"1951\" data-end=\"1991\"\u003eGrey PVC outer sheath for durability\u003c\/li\u003e\n\u003cli data-section-id=\"4gv56u\" data-start=\"1992\" data-end=\"2048\"\u003eNumber-coded cores with green\/yellow earth conductor\u003c\/li\u003e\n\u003cli data-section-id=\"1vp0cll\" data-start=\"2049\" data-end=\"2076\"\u003eRated voltage: 300\/500V\u003c\/li\u003e\n\u003cli data-section-id=\"4sdlx4\" data-start=\"2077\" data-end=\"2111\"\u003eFlame retardant to IEC 60332-1\u003c\/li\u003e\n\u003cli data-section-id=\"zpgesb\" data-start=\"2112\" data-end=\"2276\"\u003eManufactured to BS EN 50525-2-11 standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"jrpqml\" data-start=\"2283\" data-end=\"2332\"\u003eReliable Signal Integrity for Control Systems\u003c\/h3\u003e\n\u003cp data-start=\"2334\" data-end=\"2750\"\u003eThe Pitacs P5CY 5 Core CY Control Flex Cable is designed for applications where electrical interference can compromise signal accuracy. The tinned copper braid screen provides effective shielding against EMI generated by motors, switchgear and industrial equipment, ensuring consistent and reliable transmission of control and instrumentation signals.\u003c\/p\u003e\n\u003cp data-start=\"2752\" data-end=\"3036\"\u003eIts fine stranded copper conductors offer excellent flexibility, making installation easier in confined spaces such as control cabinets, ducts and machinery enclosures. The 5 core configuration allows for more complex control, monitoring and automation circuits within a single cable.\u003c\/p\u003e\n\u003ch3 data-section-id=\"858m9l\" data-start=\"3043\" data-end=\"3068\"\u003eTechnical Information\u003c\/h3\u003e\n\u003cul data-start=\"3070\" data-end=\"3695\"\u003e\n\u003cli data-section-id=\"10r8myw\" data-start=\"3070\" data-end=\"3098\"\u003eVoltage Rating: 300\/500V\u003c\/li\u003e\n\u003cli data-section-id=\"y9c1uj\" data-start=\"3099\" data-end=\"3129\"\u003eConductor Material: Copper\u003c\/li\u003e\n\u003cli data-section-id=\"1guaiix\" data-start=\"3130\" data-end=\"3180\"\u003eConductor Type: Fine stranded copper (Class 5)\u003c\/li\u003e\n\u003cli data-section-id=\"xi9as7\" data-start=\"3181\" data-end=\"3211\"\u003eCore Configuration: 5 Core\u003c\/li\u003e\n\u003cli data-section-id=\"1d3h8zw\" data-start=\"3212\" data-end=\"3240\"\u003eInsulation Material: PVC\u003c\/li\u003e\n\u003cli data-section-id=\"1hax8h2\" data-start=\"3241\" data-end=\"3271\"\u003eOuter Sheath Material: PVC\u003c\/li\u003e\n\u003cli data-section-id=\"1v4pe7g\" data-start=\"3272\" data-end=\"3308\"\u003eScreen: Tinned copper wire braid\u003c\/li\u003e\n\u003cli data-section-id=\"1ibveu4\" data-start=\"3309\" data-end=\"3350\"\u003eOperating Temperature: -15°C to +60°C\u003c\/li\u003e\n\u003cli data-section-id=\"14a32go\" data-start=\"3351\" data-end=\"3387\"\u003eShort Circuit Temperature: 150°C\u003c\/li\u003e\n\u003cli data-section-id=\"1b56rqo\" data-start=\"3388\" data-end=\"3444\"\u003eMinimum Bending Radius: approx. 4–5 × cable diameter\u003c\/li\u003e\n\u003cli data-section-id=\"155esll\" data-start=\"3445\" data-end=\"3494\"\u003eSuitable for indoor dry and damp environments\u003c\/li\u003e\n\u003cli data-section-id=\"11napcl\" data-start=\"3495\" data-end=\"3695\"\u003eDesigned for industrial control and instrumentation use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"gw7fam\" data-start=\"3702\" data-end=\"3734\"\u003eAdditional Technical Details\u003c\/h3\u003e\n\u003cul data-start=\"3736\" data-end=\"4270\"\u003e\n\u003cli data-section-id=\"15hnfwc\" data-start=\"3736\" data-end=\"3760\"\u003eUK designation: P5CY\u003c\/li\u003e\n\u003cli data-section-id=\"17rx6v9\" data-start=\"3761\" data-end=\"3792\"\u003eStandards: BS EN 50525-2-11\u003c\/li\u003e\n\u003cli data-section-id=\"u5gf0p\" data-start=\"3793\" data-end=\"3856\"\u003eCore identification: numbered cores plus green\/yellow earth\u003c\/li\u003e\n\u003cli data-section-id=\"18n2oy8\" data-start=\"3857\" data-end=\"3880\"\u003eSheath colour: grey\u003c\/li\u003e\n\u003cli data-section-id=\"1dcyeed\" data-start=\"3881\" data-end=\"3939\"\u003eSuitable for measuring, monitoring and control systems\u003c\/li\u003e\n\u003cli data-section-id=\"z8vjq6\" data-start=\"3940\" data-end=\"4001\"\u003eIdeal for manufacturing and process control installations\u003c\/li\u003e\n\u003cli data-section-id=\"1eksqhq\" data-start=\"4002\" data-end=\"4072\"\u003eAvailable in conductor size 0.75mm²\u003c\/li\u003e\n\u003cli data-section-id=\"nhq5u1\" data-start=\"4073\" data-end=\"4137\"\u003eSupplied in coils or drum lengths depending on specification\u003c\/li\u003e\n\u003cli data-section-id=\"17w0z1b\" data-start=\"4138\" data-end=\"4226\"\u003eCurrent carrying capacity varies depending on conductor size and installation method\u003c\/li\u003e\n\u003cli data-section-id=\"1nyde18\" data-start=\"4227\" data-end=\"4270\"\u003eDesigned for EMC-sensitive environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1ort0kt\" data-start=\"4277\" data-end=\"4298\"\u003eWhat’s in the Box\u003c\/h3\u003e\n\u003cul data-start=\"4300\" data-end=\"4357\"\u003e\n\u003cli data-section-id=\"paamvx\" data-start=\"4300\" data-end=\"4357\"\u003ePitacs P5CY 5 Core CY Control Flex Cable (coil or drum)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wv8cei\" data-start=\"4364\" data-end=\"4375\"\u003eSummary\u003c\/h3\u003e\n\u003cp data-start=\"4377\" data-end=\"4757\"\u003eThe Pitacs P5CY 5 Core CY Control Flex Cable provides a reliable, interference-protected solution for control and instrumentation wiring. With its tinned copper braid screen, flexible stranded copper conductors and durable PVC construction, it delivers stable performance in industrial, commercial and building control systems where signal integrity and reliability are essential.\u003c\/p\u003e","brand":"Pitacs","offers":[{"title":"1m \/ 0.75mm \/ Grey (Numbered Black Green\/Yellow)","offer_id":57726765793612,"sku":"P5CY0.75D1","price":1.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/3757\/4988\/files\/Control-P5CY-2000px.png?v=1780350490","url":"https:\/\/ioelectrics.co.uk\/products\/pitacs-p5cy-5-core-cy-control-flex-cable","provider":"io Electrics","version":"1.0","type":"link"}