{"product_id":"warmup-powerbreaker-rcd-spur","title":"Warmup Powerbreaker RCD Spur","description":"\u003ch2\u003e\u003cspan\u003eWarmup Powerbreaker RCD Spur\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eWarmup Powerbreaker RCD Spur\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a combined residual current device and fused spur designed to provide electrical protection and isolation for Warmup electric underfloor heating systems. It provides a dedicated means of supplying and protecting the heating system, helping ensure the installation meets the appropriate electrical protection requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDesigned for use with Warmup electric underfloor heating, the Powerbreaker combines an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRCD and fused spur\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in a single unit, providing a practical solution where dedicated protection is required for an underfloor heating installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eCombined RCD and fused spur\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e - Integrates residual current protection and fused isolation in one unit.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e30mA RCD protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e - Provides the required residual current protection for compatible electric underfloor heating installations.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDesigned for Warmup systems\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e - Suitable for use with Warmup electric underfloor heating systems.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDedicated heating circuit protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e - Provides a dedicated point of protection between the electrical supply and heating system.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFused spur functionality\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e - Allows the heating system to be isolated from the electrical supply when required.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePractical installation solution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e - Combines two essential electrical functions within a single accessory.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSuitable for thermostat installations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e - Can be used to supply power to a Warmup thermostat controlling an electric heating system.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eElectrical Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWarmup specifies that its electric underfloor heating systems must be protected by a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e30mA RCD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The RCD continuously monitors the electrical current and is designed to disconnect the supply if an imbalance associated with a fault is detected.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Powerbreaker provides this residual current protection alongside fused spur functionality, making it suitable for installations where a dedicated RCD-protected supply is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Information\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Warmup\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProduct:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Powerbreaker RCD Spur\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProduct Type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e RCD \/ Fused Spur\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eResidual Current Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Electric underfloor heating\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFunction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Residual current protection and fused isolation\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eCompatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Warmup electric underfloor heating systems\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInstallation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Fixed electrical installation\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eElectrical Supply:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Mains supply\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFuse:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Fused spur configuration\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Warmup Powerbreaker RCD Spur should be installed as part of the electrical supply to the underfloor heating system and connected in accordance with the relevant wiring regulations and Warmup installation instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWarmup's installation guidance specifies that the heating system must be protected by a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e30mA RCD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, either through a dedicated RCD or an existing RCD-protected circuit where the circuit is suitably rated for the additional load.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe final electrical connection to the mains supply must be completed by a suitably qualified electrician. The electrician should confirm that the electrical supply, protective devices and connected heating load are appropriate for the installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eSuitable Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Warmup Powerbreaker RCD Spur is suitable for use with Warmup electric underfloor heating installations in:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBathrooms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eKitchens\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLiving rooms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBedrooms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHallways\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConservatories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEn-suites\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOther domestic and commercial areas using compatible Warmup electric heating\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eImportant Information\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe RCD protection requirements and maximum connected heating load should be assessed by the electrician as part of the installation. Warmup's installation documentation specifies different maximum heating loads per 30mA RCD depending on the heating system, so the applicable installation manual should always be followed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAll electrical installation work should be carried out by a suitably qualified electrician in accordance with current UK wiring regulations and the manufacturer's instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhy Choose the Warmup Powerbreaker RCD Spur?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eWarmup Powerbreaker RCD Spur\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a convenient combined solution for protecting and isolating an electric underfloor heating installation. By incorporating \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e30mA residual current protection and fused spur functionality\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e into one accessory, it provides a straightforward way to supply compatible Warmup electric underfloor heating systems safely and appropriately.\u003c\/span\u003e\u003c\/p\u003e","brand":"Warmup","offers":[{"title":"Default Title","offer_id":58872996528460,"sku":"Residual Current Device (RCD\/Fused Spur)","price":55.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/3757\/4988\/files\/warmup-rcdpd_20.jpg?v=1789768379","url":"https:\/\/ioelectrics.co.uk\/products\/warmup-powerbreaker-rcd-spur","provider":"io Electrics","version":"1.0","type":"link"}