{"product_id":"warmup-under-tile-heater","title":"Warmup Under Tile Heater","description":"\u003ch2\u003e\u003cspan\u003eWarmup Under Tile Heater\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCreate a warm, comfortable and inviting floor with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eWarmup Under Tile Heater\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, an electric underfloor heating solution designed for installation beneath tiled and stone floor finishes. Ideal for bathrooms, kitchens, conservatories and other areas where tiled floors can feel cold, the system provides gentle radiant heat across the floor surface while remaining discreet beneath the finished flooring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Warmup Loose Wire under-tile heating system is particularly well suited to small, irregularly shaped rooms and areas containing permanent fixtures, allowing the heating cable to be positioned around obstacles, corners and fittings. The system can be installed within a layer of flexible tile adhesive beneath tiles or within suitable levelling compound beneath other compatible floor finishes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDesigned for tiled floors\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e - Ideal for use beneath ceramic and natural stone tiles.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFlexible installation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e - The loose heating cable can be arranged around fixtures, corners and irregularly shaped areas.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eUltra-thin heating cable\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e - The heating cable has a diameter of just \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1.8mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping to minimise any increase in floor height.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e150W\/m² output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e - Provides an effective level of radiant heat for comfortable tiled floors.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDual-core heating cable\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e - Constructed with advanced fluoropolymer insulation for durability and reliable performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e3m cold tail\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e - Supplied with a 3m cold connection lead to assist with installation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePrimary or secondary heating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e - Suitable for use as either a primary or secondary heat source where the installation meets the required building and insulation standards.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLifetime warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e - Warmup provides a Lifetime Limited Warranty for the Loose Wire system.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSafetyNet Installation Guarantee\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e - If the heating system is accidentally damaged during installation, Warmup's SafetyNet guarantee can provide a replacement heater subject to its terms and conditions.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eHeating Performance\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Warmup Under Tile Heater provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e150W\/m²\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e of electric underfloor heating, delivering radiant warmth directly through the tiled floor. Tiles and stone are particularly suitable for underfloor heating because they have high thermal conductivity, allowing heat to transfer efficiently to the floor surface while retaining warmth effectively.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe system can be used as either a primary or secondary heating source, depending on the insulation levels, room characteristics and heat-loss requirements of the installation. Warmup recommends carrying out an appropriate heat-loss calculation where underfloor heating is intended to provide the main source of heating.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Information\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSystem:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Warmup Loose Wire \/ DWSWire\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Under-tile electric underfloor heating\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeating Output:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 150W\/m²\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOperating Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 230V AC, 50Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeating Cable Diameter:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1.8mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eCable Construction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Dual-core heating cable\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInsulation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Advanced fluoropolymer (ETFE)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eCold Tail Length:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3m\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eRecommended Floor Finish:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ceramic and natural stone tiles\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInstallation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Within flexible tile adhesive beneath tiles\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeating Cable Spacing:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Adjustable between 50mm and 100mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWarranty:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Lifetime Limited Warranty\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eInstallation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe heating cable can be positioned across the required heated area and manoeuvred around fixed objects and irregular sections of the room. Unlike a pre-spaced heating mat, the Loose Wire system allows the spacing between cable runs to be adjusted to suit the installation, with Warmup specifying a spacing range of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e50mm to 100mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe heating cable must not be cut or shortened. The correct heater size should therefore be selected according to the net heated floor area. The entire heating element must be fully embedded within suitable flexible tile adhesive or levelling compound, with no sections left exposed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFollowing installation, the underfloor heating should not be switched on until the tile adhesive or screed has fully cured. Warmup recommends allowing a minimum of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e7 to 10 days\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e before activating the system, subject to the adhesive manufacturer's instructions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIdeal Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Warmup Under Tile Heater is suitable for a wide range of tiled areas, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBathrooms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eKitchens\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEn-suites\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConservatories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHallways\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUtility rooms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIrregularly shaped rooms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAreas with multiple permanent fixtures\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor regularly shaped rooms, Warmup also offers its StickyMat system, while DCM-PRO provides an alternative heated decoupling system designed particularly for tiled floors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eImportant Information\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAll electrical connections, including thermostat installation and wiring, must be completed by a suitably qualified and certified electrician. The heating element must not be cut, shortened, crossed or overlapped during installation. Always follow the Warmup installation instructions and ensure that the chosen tile adhesive, grout and floor finish are suitable for use with electric underfloor heating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor the best performance, Warmup recommends appropriate insulation beneath electric underfloor heating systems to reduce downward heat loss and improve heat-up times.\u003c\/span\u003e\u003c\/p\u003e","brand":"Warmup","offers":[{"title":"2.4m² \/ 22m \/ 300W","offer_id":58872998429004,"sku":"DWS300","price":132.76,"currency_code":"GBP","in_stock":true},{"title":"3.4m² \/ 34m \/ 400W","offer_id":58872998461772,"sku":"DWS400","price":157.82,"currency_code":"GBP","in_stock":true},{"title":"4.4m² \/ 44m \/ 600W","offer_id":58872998494540,"sku":"DWS600","price":231.15,"currency_code":"GBP","in_stock":true},{"title":"5.9m² \/ 64m \/ 800W","offer_id":58872998527308,"sku":"DWS800","price":298.93,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0808\/3757\/4988\/files\/DWS300.jpg?v=1789762815","url":"https:\/\/ioelectrics.co.uk\/products\/warmup-under-tile-heater","provider":"io Electrics","version":"1.0","type":"link"}